Intel RMSP3AD160F RAID Module Trimode RAID Firmware 50.8.0-2857
Dosya tipi: Firmware.
Işleti̇m Si̇stemi: AnyOS.
Dosya adı: Intel_35xx_MR_iMR_FWPKG-50.8.0-2857_pv.zip.
Bit: 32/64 Bit.
Li̇sans: Ücretsiz.
Açıklama
Version Numbers:
– Current Package Details:
– Firmware Package: 50.8.0-2857 (MR 7.8p1)
– Firmware 5.080.00-2758
– MR PL 09.25.05.00
– ROMENV 1.12
– BootBlock 7.02.00.00-0021
– NVDATA 5.0800.04-0005
– UEFI_Driver 0x07080401 (SIGNED)
– Hii v07.08.05.00 (SIGNED)
– BIOS 7.08.02.0
– SBR: 5.0803.04-0407
Firmware Changes:
SCGCQ02011203 – Controller Fatal Error is observed when Guest OS is reset from host in VMware environment
SCGCQ02069532 – PFA condition was not detected
SCGCQ02097613 – Hotspare creation with smaller size disk doesnt throw any error
SCGCQ02208517 – Diag test fails
SCGCQ02017502 – When drive is pulled keep last valid slot number in Events Generated. This was introduced with changesets SCGCQ01520443 and SCGCQ01584278
SCGCQ02032483 – Un-Hide Drive Group is enabled after hiding a VD in HII
SCGCQ02044166 – Controller hang when MR is passthrough to the VM
SCGCQ02053681 – Avoid sending intercore request to copy core1 holding buffer every 10ms
SCGCQ02020100 – Unable to simulate bad flash with LB/LBP
SCGCQ02111647 – Data corruption found while running I/O’s on 5 drive R5 vd with rebuild walk
SCGCQ02127010 – OS shutdown hangs due to Flush cache DCMD not completed
SCGCQ02206647 – Added prints and debug routine
SCGCQ02209125 – Initialize cache after diagnostics testing
SCGCQ02012425 – Handle SMART copy back failures and drive removals gracefully
SCGCQ02029933 – skip the link test if there is no qualifying pd attached
SCGCQ02034996 – PL Fault 00005853, while doing two copyback operations on lds with different block size.
SCGCQ02069166 – Controller no longer accessible after poweroff and poweron VMware virtual machine (VMware passthrough enabled)
SCGCQ02204725 – recon with PD in offline state following OCR may cause pin cache code to go into infinite loop
SCGCQ01838706 – Disable TransportReady In ICMR1
SCGCQ02201861 – Fix needed for NVME drives that identify with WriteUncorr=0 (puncturing not supported) when BadBlocks are injected on all drives and Rebuild is initiated
SCGCQ02203957 – SATA BBM not handled properly in Patrol Read
SCGCQ02203962 – Unterminated SGL is causing PL to reject cmd. Subsequent attempt to recover (through double buffering) causes FW to crash.
SCGCQ02035781 – ICMR1 With Storlibtest (OOB) TR can be enabled on VD’s it should be disabled
SCGCQ02126178 – MR7.10-9480-8i8e: DC during Single Dip COL using Automation
SCGCQ02210912 – Controller asserted after issuing ONFI BBLIST RECLAIMALL cmd to clear full BBLIST; 0x80 entries.
SCGCQ02042675 – Fix the memory allocation issue for diag test
SCGCQ02201867 – Fix for looping behavior triggering repeated MR BIOS resets on injected error conditions by simulating NVCache HW part failure
SCGCQ01996044 – MegaRAID Event Log discards old Event Log across OCRs.
SCGCQ02007828 – Possibility of data loss due to abrupt/asynchronous warm reset
SCGCQ01906471 – unsupported completion timeout capabilities don’t cause init failure
SCGCQ01904851 – Discovery may not complete, timeout on 94xx-8i HBA
SCGCQ01892105 – E40A fault if WRPROTECT or RDPROTECT is nonzero
SCGCQ01891238 – PCIe switch downstream virtual ports report SAS address of zero in SES page 0xA
SCGCQ01887433 – PLI control requests may return incorrect status when backend PCIe support is disabled
SCGCQ01886810 – NVMe I2C Backplane Detection fails on HBA connectors C2/C3 resulting in Slots not responding to LED updates
SCGCQ01886012 – link fails to come up after a surprise down
SCGCQ01870862 – port enable timeout and discovery failure with multiple VPP device configurations
SCGCQ01870842 – SAS/SATA devices not discovered with partial backplane configuration
SCGCQ01868375 – Fault 0x2805 encounter if one configures NVME and AutoPortEnable at the same time
SCGCQ01868009 – Fault 0xED22 seen on bootup
SCGCQ01859166 – Fault 0xECAD while issuing controller reset in Ex1 configuration
SCGCQ01858809 – Avoid PCIe reset request to FRU Port Descriptor unsupported PCIe drive types in DFC slots
SCGCQ01857152 – Handle partial PCIe Link configs for SFF TA 1005 UBM support
SCGCQ01856283 – CBB linker warns of overlapped sections
SCGCQ01850721 – MCTP: Fault 0x265D when packet with StartOfMsg is set and PktSeqCount is 1
SCGCQ01850593 – 0x7211 Fault hit with more than one Ux4 midplanes attached
SCGCQ01838839 – Immediately rm for cache offload when TTY log is set to be preserved
SCGCQ01849986 – Forcing rebuild of multiple drives while activity is occurring can have data misdirected to the wrong drive and hit an assertion.
SCGCQ01864432 – erroneous configurable PD count decrement
SCGCQ01870199 – Raid volume(using SED drives ) can not be secured after assigning multiple non-SED DHSP
SCGCQ01871037 – When checking the config sequence number mismatch, need to cover system PDs.
SCGCQ01871061 – Update NumberOfPciSwitches in pliRuntimeConfig at SOD
SCGCQ01873044 – erroneous configurable PD count decrement
SCGCQ01876232 – Unmap VD foreign import failure
SCGCQ01877036 – iMR global fault LED does not get lit up during fail or UBAD
SCGCQ01878300 – Fw downgrade from 7.8 to lower version that does not support unmap
SCGCQ01880124 – Disable debug queue support
SCGCQ01880847 – Hit PL Fault 00005862 LinkRegister 01439171 During CC With Triple Media Errors On R60 4K Drives
SCGCQ01884199 – FW downgrade blocking for JBOD personality used incorrect FW version number
SCGCQ01889215 – MR7.8 9480-8i8e: IO dropped on EPD during overnight cable pull/push
SCGCQ01889482 – MR_7.8:Driver unload and leave the system overnight, result to Assertion
SCGCQ01889717 – Unmap operation during init/recon/rebuild/copyback
SCGCQ01890070 – MR7.8-9460-16i: Controller Profile 14 still show SAS/SATA PDs
SCGCQ01890955 – Secure LD Creation with Dedicate Hot spare fails
SCGCQ01891177 – FW reports that the board passed BBU Retention test on boards that have a non operational ONFI NAND memory.
SCGCQ01893479 – On ESXi6.7U1 OS, With the IMR controller IOMMU fault is observed with the latest driver
SCGCQ01897779 – No profile reported when a bad (0-byte) drive is inserted
SCGCQ01902159 – MR7.8: Locate a UBad drive on SGPIO no LED blinking (Still stays as UBAD)
SCGCQ01906056 – Handle reentrancy of Snap dump creation & correct run time pinned cache snap dump handler
SCGCQ01906705 – Correct the Check Condition status reported by MR FW when a RAIDed slot behind a vSES device is accessed
SCGCQ01909346 – FW hang at POST because of continuous FW log print ” parseMuError: VF 4 – FMU Error Status 0x00000000 “
SCGCQ01912560 – foreign import failed when sequence number mismatch
SCGCQ01915675 – At booting POST screen, boot message indicating exceeding disks limit of 138 devices but the actual count is only 48 in system
SCGCQ01915880 – Controller crashes when creating secured Vd using controller encryption option
SCGCQ01916098 – MR7.8 OEM: WT VD created on attempt to create WB VD
SCGCQ01918724 – Snapdump generation in KA scenario results to CPU 0 exception or hang condition
SCGCQ01921307 – MR FW asserted after copyback completed and the source drive was removed.
SCGCQ01922023 – Controller not responsive
SCGCQ01929759 – [MR 7.8] Recursive snapdump handling
SCGCQ01931954 – Discard the snapdump when a new firmware is flashed while there was a snap dump present.
SCGCQ01936961 – All NVMe LED (Good/Fault LED) lighted up after updating to PKG 1837
SCGCQ01937149 – Create Medium Error on NVME drive fail.
SCGCQ01934145 – vSES SES Page 0Ah may report same SAS address for two elements during hot remove/add of NVMe devices
SCGCQ01916779 – IOC init may fail with Host Page Size Invalid LogInfo on backend PCIe disabled FW
SCGCQ01899293 – Debug output contains multiple copies of the same information
SCGCQ01898852 – OEM SW Enclosure Amber LED stays on after reboot
SCGCQ01891340 – VRef training failures on some boards.
SCGCQ01878217 – PL: NVMe drives do not link up on non Ex4 backplane attached to an MR board
SCGCQ01876271 – SAS/SATA drives are not getting discovered with NVMe disabled firmware on both 9400-16iB0 and 9405W-16iB0
SCGCQ01864843 – Check in Revised Workaround for 0x5842 fault – Rx Dma Memory Overflow
SCGCQ01859095 – Mismatch between data coming from Page2 and PageA in vSES
SCGCQ01856306 – backend PCIe: ECD2 fault
SCGCQ01760839 – 8GB DDR ECC event logging issue
SCGCQ01816769 – Maintain integrity of Enclosure Diagnostic page status bits between MR FW internal monitoring routines and host reads
SCGCQ01848923 – Security property is always shown false for a DG when Secured VD is created via LSA in SLES 15
SCGCQ01874526 – Enable “supportClearSnapDump” API bit
SCGCQ01883439 – cache restoration failed
SCGCQ01884233 – Fix firmware parsing for Admin NVME pass through command with IOCStatus != success
SCGCQ01885194 – Only Detect 63 Drives in Mix mode enviroment (Total 64 PDs in the system)
SCGCQ01886840 – FW hit “failed element size check !! … tail pointer 65535 exceeds max 255” while OCR and rebuilding in loop
SCGCQ01904051 – Handle missing changes of CSET(SCGCQ01318495): Test for 64+ drives per enclosure
SCGCQ01905234 – This change fixes Snapdump RTT Trace feature, by completing API change that came in after testing was completed.
SCGCQ01917645 – OPAL Desteği NVME only
SCGCQ01921540 – application show “enable unmap” incorrectly
SCGCQ01928086 – With the IMR controller IOMMU fault is observed with the latest driver allow both RDPQ array or linear array.
SCGCQ01934945 – Firmware Tries to Double Free Resource Mid
SCGCQ01863348 – TM and IO Failure with NVMe Drives on PL 8.250.2.0
SCGCQ01877879 – DDF corruption after hibernation because of incorrect virtual address mappings
SCGCQ01931276 – Upto 17% performance drop observed on single drive R0 NVME drive setup
SCGCQ01920370 – host issued UNMAP cmd not handled properly when VD is offline
SCGCQ01973566 – SAS Drives Take a Long Time to Link Up and Are Not Discovered Correctly
SCGCQ01792416 – Add secure boot support
SCGCQ01871912 – Added new events for unmap policy changes
SCGCQ01864509 – NVRAM changes to store controller PCI slot and server serial number
SCGCQ01848759 – Added Desteği Triggering SnapDump
SCGCQ01845275 – Add learn complete timestamp in NVRAM struct
SCGCQ01837670 – support to query multibit ecc error by storeliboob
SCGCQ01857308 – Changing LDBBM setting
SCGCQ01870855 – Unmap policy change in 7.8
SCGCQ01818505 – Implement MR FW support to capture Windows Driver log and add to SnapDump.
SCGCQ01819147 – Max IO size set same value as JBOD and Single drive R0
SCGCQ01867056 – New unmap policy
SCGCQ01851716 – Add support to identify the presence of the switch in 7.8
SCGCQ01985917 – Disable unmap feature on R5/6 only
SCGCQ01857051 – Attaching multiple PCIe switches may cause IOP memory corruption
SCGCQ01995099 – Number of slots for virtual SES is incorrect in StorCLI
SCGCQ01931043 – PL Fault 0x6001 occurred while running IOs + Task Management requests
SCGCQ01926166 – IO’s can time-out after controller receives an unconfirmed response from a drive
SCGCQ01924984 – Add workaround for SATA drive not complaint with ACS-3
SCGCQ01906082 – Ux4 drives not discovered in Polling Mode with HFCx16 and x8
SCGCQ01891218 – Locate LED cannot be turned off after diag reset
SCGCQ01887446 – All Ux4 drives are not discovered in x8 or x16 HFC mode while hot-plugging
SCGCQ01876864 – 0x6004 Fault running TM only test
SCGCQ01873143 – Locate LED on SFF-TA-1005 Ux4 backplanes configured in x16 or x8 HFC emulation mode is not activated by storcli command
SCGCQ01837506 – Customer specific 3108 PCIe add-on card fails to come back while resuming from sleep state S3
SCGCQ01838008 – User unable to switch personality back after a blocked FW update with a pending personality change.
SCGCQ01849356 – Error restoring offloaded (single image controller) cache with pinned cache when power is pulled during the flush ( double dip scenario ).
SCGCQ01849505 – Line 535 in ../../raid/cachePreserve.c for trying to create Pinned Cache by Cable Pull.
SCGCQ01855150 – FW breaks into montask with exceptional core handling error
SCGCQ01862592 – Cryptographic erase operation is failing from Open Manage GUI
SCGCQ01866206 – dirty led not set on in case of supercap not present even though dirty cache is present
SCGCQ01868896 – Change the reserve field in structure mode param to follow spc4 spec
SCGCQ01875268 – Controller fail to be detected by BIOS and OS after FW downgrade MR73 with COL.
SCGCQ01876281 – Sotrlci Hide/Unhide command output display incorrect status
SCGCQ01876285 – MR_DCMD_OOB_STATUS_POLL doesn’t return any events
SCGCQ01881150 – Controller can not correctly detected smart error SATA HDD.
SCGCQ01882466 – Unnecessary prints logging while issuing DCDB commands
SCGCQ01889448 – Implementation of Degraded media disablement is not working in eHBA mode.
SCGCQ01892583 – Error LED cannot stay long when drive pulled from VD.
SCGCQ01900924 – Exposing Write cache as disabled to host for a performance improvement
SCGCQ01911910 – FW can not inject Medium error into customer NVMes drive with big size of 4.0Tb
SCGCQ01914075 – Disable ONFI Flash backup of ttylog feature
SCGCQ01917764 – ONFI BBL reassignment: COL loop on power glitch during initial COL.
SCGCQ01917992 – iMR Controller crashes during IO DMA operation
SCGCQ01925570 – On UG bad PD removal and replaced with UG good PD, iMR allows Vd creation using 33 Pds
SCGCQ01932019 – Observed Fatal Firmware Error during SLES 12 O/S installation.
SCGCQ01944953 – Cannot be done initialize even if execute Full Initialize by using StorCli
SCGCQ01961977 – During drive spin up, drives come up as 0 bytes
SCGCQ01995096 – Data Abort Exception observed while running reboot test with a bad drive.
SCGCQ01983403 – additional robustness for hot reset during SAS cycle case
SCGCQ01961503 – (vSES) Injecting error on I2C channel of one connector module will cause LED of another connector module to not work.
SCGCQ01941125 – Use full Slot Cap Physical Slot Number field info for PCIe SW attached device slot enumeration
SCGCQ01918898 – SAS, SATA drives in UBM backplane(SFF-TA-1005) are not discovered when PCIe support is disabled
SCGCQ01907168 – Locate LED cannot be turned off after diag reset for few drives on Ex1
SCGCQ01867241 – IF “MODE F” successful, then without reboot/OCR application is not showing the updated drive firmware version.
SCGCQ01873090 – Assertion is hit during region lock release due to inconsistent region lock promotion related variables
SCGCQ01875086 – BIOS Handshake breaks Manufacturing Environment, need change in TTY and/or add timeout in FW for BIOS Handshake
SCGCQ01886610 – 9440-8i / 9460-16i cards BCA_S LED state doesn’t match with BCA-S LED Behavior Rule.
SCGCQ01886615 – CIT: Same EID assigned to 2 controllers
SCGCQ01886617 – Same EID assigned to 2 controllers
SCGCQ01889455 – Remove BAIL OUT message for successful partial vd creation command
SCGCQ01891918 – PD Operations like PD clear and Cryptographic Erase not blocked during personality switch in pending
SCGCQ01907155 – Can’t import foreign config (2 pd R0 split across 2 pcie switches) after powering switch back on
SCGCQ01915560 – Cached Discarded during boot
SCGCQ01920135 – Incorrect clearing of GUID to target ID map table during EPD creation
SCGCQ01921441 – MR fw doesn’t report that SAS_SATA 6 G and 3G capability
SCGCQ01925038 – Fw hit drvspinup.c when wake up from hibernation
SCGCQ01965351 – 9460-8i:”Other Error Count” of drives increase when running dd test
SCGCQ01988162 – Incorrect checks for LD invalid cases during IO processing caused data abort
SCGCQ01967743 – SATA: IO Timeouts with Read/Write and Non-Automated IO
SCGCQ01942971 – 0x6001 Fault while running IOs and doing cable pulls
SCGCQ01906462 – [vSES] Vendor ID and Product ID of Configuration diagnostic page uses hardcoded values.
SCGCQ01893314 – Incorrect vSES Data for Page 0x02 After Storcli Start & Stop Locate Operations for certain NVME Backplanes.
SCGCQ01883332 – pl: vSES reports incorrect product revision level in SES page 1
SCGCQ01872931 – Fault 4311 when running repeated controller resets
SCGCQ01846010 – support to query multibit ecc error by storeliboob
SCGCQ01824831 – Add maintenance code to avoid incorrect addition of code that can cause MR firmware hang.
SCGCQ01851700 – VD enumeration not consistent in Foreign preview menu in eHBA personality mode.
SCGCQ01862595 – GUID target ID map table is Invalidated on Insertion of off-lined drives
SCGCQ01876112 – Raid LD tgtId does not persist through OCR
SCGCQ01957294 – Often on PD insert PD Fault is asserted,de-asserted
SCGCQ01855060 – Fix BST Scripts to Account for New Allowed UART Logs
SCGCQ01935118 – Hit PL Fault 00005862 LinkRegister 01439171 During CC With Triple Media Errors On R60 4K Drives
SCGCQ01995232 – vSES: CRIT or NON CRIT bits in Enclosure Status Diagnostic page are never set.
SCGCQ01988181 – Data Abort Exception on abrupt powerloss/reset when flushing events from NVRAM hold buffer to flash
SCGCQ01983381 – Firmware Takes a Long Time to Grant Spinup to Some Drives/Phys
SCGCQ01972786 – Customer specific back plane not detected in the latest code phase
SCGCQ01944367 – (NVME) Fw Fault (faultcode 0xEC56) hit while performing system reboot test with NVMe drives attached.
SCGCQ01943907 – Firmware hits Kill Adapter when create/initialize R0 VD using 4k drive.
NVDATA Changes:
Miscellaneous changes for various products
Hii Changes:
SCGCQ01890540 – HII allows user to enter 41 alphanumeric characters as activation key instead of 40
SCGCQ01902176 – Unable to manually create an NVMe VD from HII BIOS using (9460-8i)
SCGCQ01874659 – Add new error code for UNMAP
SCGCQ01891725 – HII shows incorrect value (NA) for Fan in hardware components under basic hardware status.
SCGCQ01891488 – Inconsistent Fan status seen in HII under View Enclosure status when two enclosures connected.
SCGCQ01876262 – Help string is missing for Enter Security Key For Locked Drives and Add /s unit for MR_PD_SPEED_PCIE
SCGCQ01897268 – HII – Strip size is displayed as segment size in Virtual drive properties.
SCGCQ01735505 – Implement support for Pass-thru commands for NVME devices in Pre-Boot environment
SCGCQ01803319 – Unmap: Define new events for enhanced UNMAP support [MR7.8]
SCGCQ01868434 – Change the Firmware Name Field in the Inventory data
SCGCQ01797424 – Including The Time Stamp for every Snap Dump created in the firmware.
SCGCQ01869868 – UNMAP SAS/SATA feature – Mixing PDs
SCGCQ01823919 – Support UNMAP/TRIM/WRITESAME for SAS/SATA PDs with R5/6 configurations
SCGCQ01818155 – UEFI reports boot drivers issue on every bootup
SCGCQ01856123 – Profile based LD creation thrown error from HII
SCGCQ01917148 – Customize 4K and 512B mixing error string and add help string for Current Drive Security Mode
SCGCQ01917085 – HII does not notify user regarding the OS/FS on trying to delete a single JBOD drive
SCGCQ01798986 – “Suggest Security Key” Function corrupts the “Existing Key” when trying to change security key
SCGCQ01807627 – HII Secure Virtual Disk option help incorrectly states it should be selected by default when a passphrase is configured
SCGCQ01830856 – HII does not report error when creating a VD with both NVMe and SAS drives selected
SCGCQ01835613 – showing PD contains a OS/FS on a non-selected PD when converting from Non-RAID to UGood.
SCGCQ01835619 – Not able to save controller events in HII
SCGCQ01874658 – HII: The drives are not sorted based on connector name
SCGCQ01830843 – HII – Converting UGood to EPD has warning message about data on the Non-RAID disk.
SCGCQ01849748 – HII does not notify the user on selecting individual JBODs having Filesystem/ OS
SCGCQ01873518 – Check all does not select all drives that are in JBOD state while creating VD using ‘create virtual drive’ option
SCGCQ01917142 – During reconnect, ASSERT and RSOD occured
SCGCQ01807671 – HII PD Management: EPD-PTs named as Non-RAID instead of ‘Non-RAID Disk’
SCGCQ01808677 – HII: Rename ‘Secure Erase’ to ‘Cryptographic Erase’
SCGCQ01808685 – UEFI BlockIOProtocol SCT test fails with “Read block with invalid LBA parameter” failure when EPDs are present
SCGCQ01824016 – HII – PDs for Non-supported VDs are showing under the “Physical Disks Included after foreign configuration import” subtitle.
SCGCQ01827411 – HII does not allow to change the personality from Raid to JBOD
SCGCQ01835617 – HII – PD menu not auto updating after converting a UGood drive to Non-RAID.
SCGCQ01849205 – HII: Support UDK2017 AARCH64
SCGCQ01855631 – HII is not displaying the same PDs with an OS/FS present when converting to RAID Capable
SCGCQ01874605 – In BIOS HII page 16-byte model number of SATA drives not full model number is displayed.
SCGCQ01851640 – HII – The Disable Security warning should use “cryptographically erased” instead of “securely erased”.
SCGCQ01807672 – HII: Controller Mode and Requested Mode displayed on the Adv Ctrl Mgmt page instead of Manage Controller Mode page
SCGCQ01849032 – HII: correct the grayout condition to change profile
SCGCQ01804182 – Default Profile in HII reports Yes for Profile 10
SCGCQ01808664 – Change warning message for converting UG to JBOD and vice versa + correct few other string problems
SCGCQ01818098 – Remove Unmap enable/disable option for EPD Drives
SCGCQ01830853 – HII does not exclude virtual drives when scheduling consistency check
SCGCQ01851505 – HII – Incorrectly showing a OS/FS on a non-selected PD when converting from Non-RAID to UGood.
BIOS Changes:
SCGCQ01806553 – JBOD handled message is displayed twice in JBOD mode
SCGCQ01837611 – In Legacy BIOS Post battery shows “Optimal” while the battery is not connected.
SCGCQ01765520 – “The Controller is in Cached Drive Drive mode.” message shown in the legacy boot POST
SCGCQ01807610 – OpROM POST displays incomplete string “No Adapter” when controller hits fault condition
SCGCQ01835626 – When Option ROM is enabled in System BIOS, behavior is unexpected
UEFI shell instructions for updating RAID Firmware:
– Tüm dosyaları indirin ve bir USB flash sürücüye çıkarın.
– Hedef sistemi EFI kabuğuna boot et.
– Yerel sürücüye dizini ve flash güncelleme dosyalarını ve bellenim imaj dosyasını içeren dizini değiştirin.
– Güncellemek için denetleyiciyle eşleşen .nsh dosyasının adını yazın (örn. “RMSP3HD080E.nsh” ve ardındankomutunu çalıştırmak için
– .nsh komutundaki storcli komut satırı ilk mantıksal RAID denetleyicisine (“/ c0”) ayar yapacaktır. Bu, birden fazla denetleyici varsa, denetleyici parametresinin (“/ Cx”) değerinin, güncelleme için amaçlanan denetleyiciyle eşleşecek şekilde değiştirilmesi gerekir.
– Flaşın tamamlanmasını bekleyin. Güncelleme sırasında sistemi yeniden başlatmayın.
– RAID ürün yazılımını güncellemek için RAID Web Konsolu 3 veya StorCLI işletim sisteminin sürümünü de kullanabilirsiniz. Daha fazla ayrıntı için lütfen Intel RAID Yazılımı Kullanıcı Kılavuzu’na bakın.
Dikkat!
– Intel, mevcut bir dizideki verileri etkilemeyecek ürün yazılımı yükseltmesinden sonra Fabrika Varsayılanı ayarını yüklemenizi önerir.
– Sistemi yeniden başlatın ve RAID BIOS Konsolu’na giriş yapın.
– Denetleyiciyi seçin ve ‘Adaptör Özellikleri’ seçeneğini seçin -> ‘İleri’
– ‘Fabrika Varsayılanlarını Ayarla’ ayarını ‘Evet’ olarak ayarlayın ve değişikliği gönderin.
– Sistemi yeniden başlatın (varsayılan ayarlar uygulanır).
– RAID Web Konsolu3’te istediğiniz ayarları yeniden yapılandırın.
Yazılım düşürme bildirimi
– Intel, RAID modülünüzde ya da denetleyicinizde fabrikada takılmış ürün yazılımını düşürmenizi önermez, önceki bir sürüme giderken kaybedebileceğiniz önemli geliştirmeler ve hata düzeltmeleri vardır.
– Eski bir üretici yazılımı sürümünü yüklemeniz gerekirse, bu işlemin nasıl yapılacağına ilişkin talimatlar için lütfen Intel’e başvurun.
İndirme