Changements:
– Added support for bandwidth monitoring according to Performance histogram in Vendor Specific MAD spec
Bug Corrections:
– Cannot enable 40GbE on backplane ports
– Reset cannot be performed during I2C operation
Known Issues:
– The SampleCounter mechanism is not supported.
– Resetting the counters of port receive packets and port receive unicast packets using “Performance class MAD” or the VL15 received packets and data counters using Mellanox Vendor Specific MAD resets all of the above counters.
– FDR link may raise as FDR10 when plugged in near an FDR10 cable.
– Link width negotiation is not supported.
– Link up negotiation may take up to 70 seconds.
– DDR link may rise with errors or at SDR speed when connecting to ConnectX®-3 version
– 2.30.3000 or earlier, Connect-IB™ version 10.10.1000 or earlier, or previous releases of SwitchX®.
– QDR capabilities at the INI must be enabled when working in FDR mode.
– Downgrading to firmware version 9.2.0000 requires power cycling the switch for the firmware to load.
– Loopback modules are not supported and do not link up.