Açıklama
sürümleri:
– BIOS: 01.01.0029
– ME: 03.01.03.072
– BMC: 01.60.12335
– FRUSDR: 1.19
Issues Fixed in BIOS 01.01.0029
– [HSD-ES][1507032918][D0249]System become unresponsive when flash the modified BIOS capsule that change offset 0x70 value from 00 to 4F
– [HSD-ES][1507164194]0xFF transport failed on serial port
– [HSD-ES][1507197471]FW-UEFI-Vuln-2019-117 [BDBA] Intel Server Board S2600TP Family – System Update Package EFI – BIOS 01.01.0024, ME FW 03.01.03.043, BMC 1.51.11142, FRUSDR 1.17
– [HSD-ES][1507218677]Include PRT patch Intel Server and Workstation Processors Microcode Update Rev. Production SRV_P_285 to Xeon E5-2600v3,v4 Family Q3 2019
– [HSD-ES][1507195983][Security] Race conditions in VariableInterface() allow arbitrary writes inside of SMRAM
– [HSD-ES][1507242883]CCB#2664:[BIOS] Add correctable error thresholds for 100 and 500
– [HSD-ES][1507238702]The copyright should be Copyright (c) 2010-2019 instead of Copyright(c) 2010-2018
– [HSD-ES][1507284801]Xeon E5-2600v3,v4 Family Security version update to version 1111
– [HSD-ES][2207342514]Injection of Malformed TLP into PCH slot shows no system reponse
– [HSD-ES][1507402292][S2600KP]Syscfg /fan command failed to change setting on S2600KP
– [HSD-ES][1607116940]Add two BIOS PCIe options for each PCIe slot’s add-in card into BIOS setup/Syscfg/ITK options when PCIe Advance Error Reporting feature(AER) is enabled.
– [HSD-ES][1507689901]The copyright should be Copyright (c) 2010-2020 instead of Copyright(c) 2010-2019
– [HSD-ES][1507349222]Unsecure write to SMRAM because of missing buffer validation
– [HSD-ES][1507801623][H1 #744766] SMM-module – MemRas – Missing pointer validatio S2600
– Update 0x38 Microcode for IPU2019.2
– Update ME to 03.01.03.072 for IPU2019.2
– Update SINT ACM: 3.1.3 for IPU2019.2
– [HSD-ES][1507430121]:Xeon E5-2600v3,v4 Family BIOS KCS fix
– [HSD-ES][2103632349]SOL options in BIOS setup can be operated when KCS mode change to Restricted or Deny All.
– [HSD-ES][1507896793]SUT will halt at post code 0x81 when downgrade BIOS from D52 to R28.
– [HSD-ES][2103632353]Set KCS mode to Deny All or Restricted, change some option, press F10 and “Y” to save, there will show a message “Submit Fail for Form: UEFI Network Stack”.
– [HSD-ES][2103632466]The BMC Firmware Revision&SDR Revision not hidden in POST Information under KCS Deny All mode.
– [HSD-ES][1507979683]Enable BT(SIO) in Pilot BMC
– [HSD-ES][1507959292]Add new KCS policy done_core flage in BT
Issues Fixed in ME 03.01.03.072
– QSR PSIRT-TA-201901-002
Issues Fixed in BMC 1.60.12335
– [BMC]After offline update BMC to 1.58, SSH can’t connect successfully by default port 22.
– [BMC]The EWS login Window can’t be opened sometimes if offline update the BMC to 1.58.
– [BMC]The SSH connection will be closed automatically after issuing some commands.
– [BMC]The SEL for capture KCS policy control mode is incorrect.
– [BMC] KCS policy sensor will show “Unknown” health status after BMC reset for BMC 1.59.
– [BMC] There is no help information about new features “RMCP mode” and “RMCP+ Cipher Suite3” in the EWS.
– [BMC]Changed any secure port of KVM/CDROM/USB/Floppy, the KVM will hang up after mount any remote media.
– The KVM session will hang up when set the “USB key Emulation Type” to “Hard Disk” type and mount the redirected devices.
– It shows, “Description:Unname – Asserted” in the SELText.txt (SELLOG.zip) for all KCS control mode.
– [BMC]The SUT can’t get the stateful IPv6 IP address from DHCPv6 server.
– [BMC]The SEL for capture KCS policy control mode is incorrect.
– Replace 05A~08A 1600W PSU fw from 75 to 78 and add 09A~11A 1600W PSU FW version 78
– Upgrade openssl from 1.1.1e to 1.1.1g
– KCS PSIRT enhancement that is for core-bios-done possible security attack
– add Cipher Suite3 setting in EWS
– add RMCP mode setting in EWS
– fix RED team reported problems including Web File upload problem and Authentication Bypass for each ASP endpoint.
– BDBA fix : libs and application upgrade (/usr/bin/unzip and /sbin/lsof removed,libldap to 2.4.49,openssl from 1.1.1d to 1.1.1e,libtasn1 to v4.16, libkrb5.so-keberos upgrade to 1.18.0)
– web page copyright date wrong problem.
– [BMC]The SSH connection will be closed automatically after issuing some commands.
– fail to dump system debug log with syscfg.
– [BMC][H1 761356] buffer overflow in usbe.ko leads to remote code execution.
– DCG RED team reported vulnerabilities fix ID#19 and improvement on ID#4,8,9 fixes.
– BDBA fix – kernel and busybox upgrade
– BDBA Fix – libs and application upgrade (libbz2, libgcrypto, libgpg-error, libsasl2, openssl, zlib, openssh, stunnel, dhclient, glibc)
– KCS PSIRT problem (refer to Xeon E5-2600v3,v4 Family BMC EPS 1.20)
– Only support Cipher suite 17 for IPMI over lan(ipmitool -I lanplus …. -C 17)
– SSH weak cipher remove
– USBanywhere security problem , need to disable unsecure port about KVM
– CCB 2880 Add IPMI commands and Web interface for user to select SSL Cipher
– expl_fdserver problem, need to fix bypass auth issue
– DCG RED team reported about 20 vulnerabilities.
– klockwork problem fix including about 2000 Critical and Error issues in different features.
Issues Fixed in FRUSDR 1.19
– Features added: Add KCS Ctrl Mode sensor & Update new FRUSDR utility ( FRUSDR_V14_1_Build18_AllOS ).
System Firmware Update Package Usage instructions
This package can be updated using one of the following methods:
– Windows or Linux operating system using Intel One-boot Flash Update (OFU) V13.1 Build 13
– Windows Preboot Execution Environment (WinPE)
To update from Windows and Linux or operating systems using the Intel One Boot
– Flash Update Utility (OFU)
Use OFU to update system firmware by the following steps:
– Install OFU on Windows or Linux system
– Download the latest firmware update package from http://downloadcenter.intel.com/
– Unzip package to a folder
– Run the following command in Windows command line/Linux terminal window: <OFU install folder name>:flashupdt -u <package folder name>flashupdt.cfg
To update from Windows Preboot Execution Environment (WinPE)
The System Firmware Update Package can be inserted to Windows PE customized image for creating a bootable Windows PE CD. User is able to update system firmware from customized WinPE CD by the following steps:
– Boot server with customized WinPE CD
– Run script “WinPE21_x64_Update.bat” or “WinPE20_x86_Update.bat” (name may be varied depends on your own customization)
Update Procedure:
– Unzip the contents of the update package and copy all files to the root directory on a USB flash drive
– Insert the USB flash drive to any available USB port on the server system to be updated
– Power on the server
– The system will automatically access the uEFI shell and begin the update process.
Or
– If the files were copied to a folder other than the root, Boot the Server to the uEFI shell. This can be accessed via the <F2> BIOS setup utility during POST or via the <F6> Boot Menu accessed during POST.
– Run the command “map -r” in the uEFI shell to mount the USB flash drive
– Run the command “fs0:” to change folders to the USB flash drive. The USB flash drive may also mount to fs1: depending on other installed devices. The number of “fs#” is dependent on the result of command “map -r”
– Change folders to the folder holding the update package files and manually start the “Startup.nsh” script file to start loading all updates
– Reboot the system after the update process has successfully completed
Verifying Updates:
– During POST, hit the <F2> Key when prompted to access the BIOS Setup Utility
– From the BIOS Setup Utility main menu, Hit the <F9> key to load BIOS Defaults
– At the MAIN menu verify the BIOS revision is correct
– Move cursor to the SERVER MANAGEMENT Menu
– Move cursor down to the SYSTEM INFORMATION Option and hit Enter
– Verify the BMC Firmware revision is correct
– Verify the SDR revision is correct
– Verify the ME Firmware revision is correct
– Configure desired BIOS Option settings
– Hit the F10 Key to save changes and Exit