Descrição
Upgrade guidelines:
– This firmware release is intended for customers with current firmware versions LW73.xx.P034, LW72.xx.P030, LW71.xx.P025, LW70.xx.P022, or older (releases where the 2 digits immediately after LW are less than 70)
– If the current firmware on the device is LW70.xx.P200 or newer (releases where the 3 digits after P are greater than 200), do NOT update to this release. Contact the Technical Support Center for a newer version of firmware.
MS310d, MS310dn, MS312dn, MS317, MS410d, and MS410dn devices:
– If device firmware is EC5 or older, update the device firmware first to LW50.PRL.P593. After the device reboots, proceed to update firmware to EC6.0 or newer.
– This intermediate update is necessary due to increased code size of EC6.0 or newer and memory usage during code updates. If attempting to load EC6.0 or newer code over EC5 or older code other than LW50.PRL.P593, it can take up to or more than 90 minutes to update or it may fail completely due to an out of memory condition.
Non-eTask Models:
– If the device was originally manufactured with EC1 code or earlier, it is possible that the DBCS (Japanese, Simplified Chinese, Traditional Chinese, and Korean) characters may go missing from the front panel display after updating firmware.
– To fix this, simply send the updfonts.fls file included in the zip package to the device. This is a smaller version that fits in the space available with no loss of characters.
Downgrading to EC4.0 or EC4.05:
– Due to changes in EC4.0 and EC5, do NOT downgrade firmware from EC5 or newer directly to EC4.0 or EC4.05 based code. EC4.0 and EC4.05 code levels have names like LW40.xx.P4xx. This will cause a non-clearable 900 Service error. Contact the TSC for instructions on how to clear this error.
– This warning includes installing a DLE with EC4.0 or EC4.05 code into a device that currently has EC5 or newer code.
– Code levels earlier than EC4.0 can be sent to EC5 level devices without causing a service error.
– To downgrade EC5 or newer code to an EC4.0 or EC4.05 level, you must first load an EC4.1 based code. EC4.1 code levels have names like LW41.XX.P4xx. Once the device is at an EC4.1 level, EC4.0 code can be sent.
– According to the firmware FAQ posted on the support site, we do not officially support downgrading firmware. This is the reason it is not supported, even though great efforts are made to prevent these kinds of events from happening, sometimes it is unavoidable. We apologize for the inconvenience.
Apps (eTask models only):
– Scan to Network app – v4.9.19
Security Issues Addressed:
– Updated Java certificates for remote operator panel access
– Security improvements based on internal testing
– Added authenticated proxy support
Field Issues Addressed and Other Improvements:
– Improvements to Scan to Network using SMBv3
– Fix issue wtih clearing the restricted server list via MVE
– Fix issue with printer not prompting for Universal media size when printing via IPP
– Improve Cloud app deployment