Sound Devices 552 Field Mixer Oprogramowanie 1.4
Typ pliku: Oprogramowanie.
System Operacyjny: AnyOS.
Nazwa pliku: 552-firmware.
Bit: 32/64 Bit.
Licencja: Darmowa.
Opis
Nowy:
– Save and load user settings to internal memory.
Poprawki:
– Improved transport control preventing semi-lockup conditions with some SD cards.
Known Issues:
– The list below are the published known issues for the latest 552 Firmware.
– SD cards 64 GB and larger are not supported.
– Intermittent issue with feeding AES/EBU from the 552 to some Sony cameras (e.g. F5, F55) where the camera will occasionally report „Input AES/EBU is not Pro Use”. Workaround: Reboot the 552 or toggle the 552 sample rate from 48kHz to 96kHz and back again.
Prepare to Update:
– Before upgrading the firmware on the 552 from the original revision 1.0 release, the digital outputs MUST BE TURNED OFF. The update will fail if the outputs are set to AES. If upgrading from any later version than 1.0, this step is not necessary.
– Download the 552 firmware file.
– From the zip archive, extract the file within. Copy this .prg file to the root level of a SD or SDHC memory card. Do not place the file in any folder. The card must be formatted as a FAT32 volume.
Apply Update to 552:
– Power the 552 from a fresh set of batteries or from external DC. Do not perform the update with low batteries or unstable power sources.
– Power down the 552 if it is already powered up.
– Connect headphones so that you can hear SVEN.
– Insert the SD card with the .prg file.
– Power on the 552. With the new firmware on the inserted SD card, the mixer will auto-detect the new file and SVEN announces „Software update, press Battery Button if OK, press Stop to cancel.”
– Press the Battery Button to continue. SVEN announces „Checking file integrity,”, then „Programming, please wait,”, then „Verifying, please wait.” When the update is complete SVEN announces „Update finished, please turn off power to complete”.
– Power down the 552.
– Power the 552 on. The meters will „dance” and briefly pause on -30 LED on the left meter and -20 on the right meter, this indicates that the 552 is running the X revision of firmware. Please note any changes or additions to the Setup Menu (if applicable).