Sound Devices 552 Field Mixer Oprogramowanie 1.3
Typ pliku: Oprogramowanie.
System Operacyjny: AnyOS.
Nazwa pliku: 552-firmware.
Bit: 32/64 Bit.
Licencja: Darmowa.
Opis
Nowy:
– fix – a rare bug in which the Tape metadata and Date stamp was incorrect on the forty-third file recorded.
– fix – a rare bug in which the meter did not always switch from the ST signal to the REC SOURCE signal.
– fix – a bug which could cause the system to get stuck in Rec Pending mode with select SD cards.
– fix – a rare condition which would cause the 552 to lockup when receiving poorly-shaped timecode.
– fix – AES Metadata information is now correct (sample rate, bit depth flags).
Prepare to Update:
– Before upgrading the firmware on the 552 from the original revision 1.0 release, the digital outputs MUST BE TURNED OFF. The update will fail if the outputs are set to AES. If upgrading from any later version than 1.0, this step is not necessary.
– Download the 552 firmware file.
– From the zip archive, extract the file within. Copy this .prg file to the root level of a SD or SDHC memory card. Do not place the file in any folder. The card must be formatted as a FAT32 volume.
Apply Update to 552:
– Power the 552 from a fresh set of batteries or from external DC. Do not perform the update with low batteries or unstable power sources.
– Power down the 552 if it is already powered up.
– Connect headphones so that you can hear SVEN.
– Insert the SD card with the .prg file.
– Power on the 552. With the new firmware on the inserted SD card, the mixer will auto-detect the new file and SVEN announces „Software update, press Battery Button if OK, press Stop to cancel.”
– Press the Battery Button to continue. SVEN announces „Checking file integrity,”, then „Programming, please wait,”, then „Verifying, please wait.” When the update is complete SVEN announces „Update finished, please turn off power to complete”.
– Power down the 552.
– Power the 552 on. The meters will „dance” and briefly pause on -30 LED on the left meter and -20 on the right meter, this indicates that the 552 is running the X revision of firmware. Please note any changes or additions to the Setup Menu (if applicable).
Pobierz