Intel S2600TP Server Board BIOS/Firmware 01.01.0019
Typ pliku: Oprogramowanie.
System Operacyjny: AnyOS.
Nazwa pliku: S2600TP_EFI_BIOS01010019_ME030103032_BMC014710181_FRUSDR114_.zip.
Bit: 32/64 Bit.
Licencja: Darmowa.
Opis
Wersje:
– System BIOS – R01.01.0019
– ME Firmware – 03.01.03.032
– BMC Firmware – 01.47.10181
– FRUSDR – 1.14
BIOS Changes:
– Rename BIOS ID from D0154 to R0019
BMC Changes:
– The HSBP’s FRU can’t be detected if install 4 HSBP in S2600WT system.
– Ping LAN1 (BMC management) IP failure after AC off/on sometimes with RoHS BB.
– HSBP3 sensors can not be accessed and shown as Unknown because of SDR auto-configuration failure
– vulnerabilities found on BMC_i_0146r9961
– BMC Ethernet hang issue in some case
– BMC alerts received in an email via SMTP have a different time
– BMC EWS Security settings issue (Bad password threshold)
– Fix issue of second CPU dump when IERR happened and first CPU dump failed, Use PCH command to trigger warm reset, Increase handshake timeout with BIOS
– Fix “No SEL is added when FM_MEM_THERM_EVENT_N is grounded.”
– Updated the stunnel conf to support TLSv1.2 only, with secured ciphers <= 128
– CCB 460: enable adoption of A1u2ULCP on S2600WT
– CCB 468: address the cipher suite zero vulnerability.
– none: update PSoC to version 1.25
– none: update SDR file for S2600WT thermal alert issue
System Firmware Update Package Usage instructions
This package can be updated using one of the following methods:
– Windows or Linux operating system using Intel One-boot Flash Update (OFU) V13.1 Build 13
– Windows Preboot Execution Environment (WinPE)
To update from Windows and Linux or operating systems using the Intel One Boot
– Flash Update Utility (OFU)
Use OFU to update system firmware by the following steps:
– Install OFU on Windows or Linux system
– Download the latest firmware update package from http://downloadcenter.intel.com/
– Unzip package to a folder
– Run the following command in Windows command line/Linux terminal window: <OFU install folder name>:flashupdt -u <package folder name>flashupdt.cfg
To update from Windows Preboot Execution Environment (WinPE)
The System Firmware Update Package can be inserted to Windows PE customized image for creating a bootable Windows PE CD. User is able to update system firmware from customized WinPE CD by the following steps:
– Boot server with customized WinPE CD
– Run script “WinPE21_x64_Update.bat” or “WinPE20_x86_Update.bat” (name may be varied depends on your own customization)
Pobierz