Intel S2600CW Server Board BIOS/Firmware 01.01.0021
Typ pliku: Oprogramowanie.
System Operacyjny: AnyOS.
Nazwa pliku: S2600CW_SFUP_BIOS01010021_ME030103043_BMC0149r10574_FRUSDR113.zip.
Bit: 32/64 Bit.
Licencja: Darmowa.
Opis
Wersje:
– System BIOS – 01.01.0021
– ME Firmware – 03.01.03.043
– BMC Firmware – 01.49.10574
– FRUSDR – 1.13
BIOS Changes:
– CCB#483: Allow ITK to change SMBIOS table OEM Strings (Type 11)
– EPSD 100256184:Fix issue PCIe card is not receiving IRQs in the second slot of customer riser
– CCB1713: Add an option in ITK to allow customer to enable/disable Spread Spectrum Clock (SSC)
– EPSD 100036011: [BDW] SMBIOS have some problem in the BCP24HDD platform with SAS bridge board
– EPSD 100036147: [BDW] Serial Port / eUSB should belong internal device not external device in SMBIOS Type8
– [HSD-ES][2103614071][BDW] BMC version show wrong in diagnostic screen
– Update copyright to 2017
– EPSD 100036010: [BDW] COM Port amount in Windows DM not match BIOS Serial Port setting
– Update RC code to v4.0.0
– EPSD 100255807: Some modules are failed in existing vulnerability test by running command “chipsec_main.py”— fix C-State lock issue
– EPSD 100255807: Some modules are failed in existing vulnerability test by running command “chipsec_main.py”— fix MsUnitDeviceFunctionHideLock issue
– EPSD 100036120 : [BDW] Press F2/F6/F12 on clear ownership interactive page will see unexpected message show up
– HSD-ES 2103614916: [BDW] A typo in the help text of Crosslink control override option, it should be DSDUSP
– HSD-ES 2103614926: UUT will halt when first 32bit of IPv6 Address/Gateway are set to a value over 32bit
– HSD-ES 1504411152: Grantley Boot performance issue (6 – 8 seconds) reported by customer inside BIOS ACPI _OSC method
– HSD-ES 2006614580: Legacy Network Device Boot Order still boots after disabling
ME Changes:
– Flash from Grantley FW to Grantley-R FW could cause SPS reset.
– System unexpected shutdown with SPS FW exception error.
– ME FW changes P state value when no policy is active imapcting performance.
– C8h command power readings for CPU domain are invalid.
BMC Changes:
– none: upgrade openssl to version 1.0.2k
– none: upgrade openssh to version 7.4p1
– CCB 1711: Need a command to check power button status
FRUSDR:
– Fix the 2HSBP issue and the 1U combo HSBP HW problem.
– Add a “SET DISABLE_NVME_FUNCTIONS” entry into CWP/KNP/TLP CFG files.
– Add the 1D SUBTYPE records in the CWP SDR file.
– Fix the HDD presence error issue.
System Firmware Update Package Usage instructions
This package can be updated using one of the following methods:
– Windows or Linux operating system using Intel One-boot Flash Update (OFU) V13.1 Build 13
– Windows Preboot Execution Environment (WinPE)
To update from Windows and Linux or operating systems using the Intel One Boot
– Flash Update Utility (OFU)
Use OFU to update system firmware by the following steps:
– Install OFU on Windows or Linux system
– Download the latest firmware update package from http://downloadcenter.intel.com/
– Unzip package to a folder
– Run the following command in Windows command line/Linux terminal window: <OFU install folder name>:flashupdt -u <package folder name>flashupdt.cfg
To update from Windows Preboot Execution Environment (WinPE)
The System Firmware Update Package can be inserted to Windows PE customized image for creating a bootable Windows PE CD. User is able to update system firmware from customized WinPE CD by the following steps:
– Boot server with customized WinPE CD
– Run script “WinPE21_x64_Update.bat” or “WinPE20_x86_Update.bat” (name may be varied depends on your own customization)
Pobierz