Dell Toshiba MG03SCA100/MG03SCA200/MG03SCA300/MG03SCA400 SAS Firmware DG09/A00
Tipo di file: Firmware.
Sistema Operativo: Windows Server 2003, Windows Server 2008.
Nome del file: SAS-Drive_Firmware_0NXTP_WN32_DG09_A00.EXE.
Bit: 32/64 Bit.
Licenza: Gratis.
Descrizione
This release contains firmware version DG09 for Toshiba drives. Vendor model numbers MG03SCA100, MG03SCA200, MG03SCA300 and MG03SCA400.
Fixes & Enhancements
Correzioni:
– VPD Page 83h byte-swap Fix. WWN will not be changed regardless of initial FW prior to FW download.
Enhancements:
– FW revision incremented to DG09 so that DG08 could be used as n-1 FW for DUP package creation.
Applies to
– TOSHIBA MG03SCA100 Series SAS 7.2K 3.5 1TB
– TOSHIBA MG03SCA200 Series SAS 7.2K 3.5 2TB
– TOSHIBA MG03SCA300 Series SAS 7.2K 3.5 3TB
– TOSHIBA MG03SCA400 Series SAS 7.2K 3.5 4TB
Installation instructions
1. Click the “Download Now” link to download the file.
2. When the File Download window appears, click “Save” to save the file to your hard drive.
Installazione
1. Individuare il percorso in cui è stato scaricato il file e fare doppio clic sul nuovo file.
2. Leggere le informazioni di rilascio presentate nella finestra di dialogo.
3. Scaricare e installare eventuali prerequisiti identificati nella finestra di dialogo prima di procedere.
4. Fare clic sul pulsante Installa.
5. Seguire le istruzioni rimanenti per eseguire l’aggiornamento.
Important Information
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.
This update will run on drives remaining in a RAID set that is in a Offline state.
There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as – The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.