Dieses Paket enthält die Dateien, die zur Installation des Treibers Gigabit Ethernet Network Connection benötigt werden. Wenn es installiert wurde, können durch Aktualisieren (Überschreiben) Probleme behoben, neue Funktionen hinzugefügt oder vorhandene erweitert werden. Auch wenn andere Betriebssysteme möglicherweise ebenfalls kompatibel sind, empfehlen wir, diese Version nicht auf anderen als den angegebenen Plattformen anzuwenden.
What’s New in This Release:
– Unterstützung für FreeBSD 11.4.
– Removed DOS tools.
Intel Ethernet 800 Series
– Fixed: Reading the module temperature sensor with NVM 2.10/2.12 gives an incorrect value for all methods that rely on firmware, including NCSI and PLDM. Users can expect reported temperature ranges from 0 to 255 with no consistency. QSFP modules with a temperature sensor whose module EEPROMs are aligned to specification SFF-8636, Revision 2.8 or newer could result in port shutdown that is only recoverable with a power cycle and a change of module.
General Intel Ethernet 700 Series Changes:
– Fixed: The Intel Ethernet Network Adapter X710-T2L/T4L and the Intel Ethernet Network Adapter X710-2/X710-4 pull-up in GLOBR creates a false FAN_ON_AUX.
– Fixed: Device returns different version of supported PLDM type 6.
– Fixed: Devices do not return Network Port schema data.
– Fixed: The FAN_ON_AUX signal doesn’t change status when temperature crosses warning threshold.
– Fixed: Intel Ethernet Converged Network Adapter XL710-Q1/Q2 recovery fails on FreeBSD.
– Fixed: RDE device reports wrong MaxFrameSize value.
– Fixed: PCIeDevice PDR (recordHandle 4003) is missing in the list of retrieved PDRs.
– Fixed: RdeOperationInit on NetworkPort1 returns SUCCESS and didn’t return BEJ.
– Fixed: For the Intel Ethernet Controller X710-TM4/AT2, setting the Link NCSI command to 2.5G/5G speed doesn’t change the link properly.
– Fixed: The NCSI Get Temperature command might try to read temperature from a module that doesn’t support temperature readings. This could lead to incorrect temperature handling as well as having an impact for handling platform events.
Intel Ethernet 700 Series Windows Driver:
– Fixed: On Windows Server 2012 R2 the host might suffer a BSOD after modifying ANS team type with tagged VLAN. It can be reproduced both with GUI or a Powershell command.
Intel Ethernet 700 Series Linux Driver:
– Fixed: MAC VLAN filters are not freed when the number of VFs changes. It is observed only when a limit of MAC VLAN filters have been reached before VF changes.
– Fixed: When the number of multicast MAC addresses configured on the VF reaches the limit of the network adapter, the VF cannot receive all multicast packets.
– Fixed: Maximum number of SR-IOV VFs is 62 (instead of 63) per port. This behavior is observed when the RSS and VMDq settings are disabled. It might be observed only when using ESX-ixgben driver.
– Fixed: Packets with assigned VLAN are not redirected to the correct queue set by the Intel Flow Director (FD) rule.
– Fixed: After setting DCB on Intel Ethernet Controller X710 adapters, traffic is not tagged with a priority tag.
– Fixed: When the second subordinate interface is added to the bonding, its MAC address becomes the same as the first added subordinate and bond interface. Reloading the PF driver and creating VFs again is needed to restore the MAC addresses.
– Fixed: Promiscuous mode trusted VF with VLAN port for unicast packets receiving additional Tx traffic of every other VFs assigned to the same PF.
Intel Ethernet 700 Series NVM Update Tool:
– Fixed: Minimum Security (Rollback) Revision (MinSREV) values and Security (Rollback) Revision (SREV) are not reported in unified (hexadecimal) format via the NVM Update Tool.
Intel Ethernet 700 Series ProSet:
– Fixed: Use Default button in the UI is missing from the Locally Administered Address tab.
General Intel Ethernet 500 Series Changes:
– Fixed: FAN 7 rotates non-stop when 562FLR is installed and while in AUX power.
– Fixed: Maximum number of SR-IOV VFs is 62 (instead of 63) per port. This behavior is observed when the RSS and VMDq settings are disabled. It is observed only when using the ESX-ixgben driver. Fixed: Firmware installation failed for 562FLR-T.
Intel Ethernet 300 Series Windows Driver:
– Fixed: The Wake on LAN (WoL) feature doesn’t work on the Intel Ethernet Server Adapter I350 and Intel Ethernet Network Adapter I350 OCP 3.0. This issue occurs on ports 2 through 4.
Um dieses Paket zu installieren, gehen Sie bitte wie folgt vor:
– Speichern Sie das herunterladbare Paket an einem zugänglichen Ort (z. B. auf Ihrem Desktop).
– Entpacken Sie die Datei und geben Sie das neu erstellte Verzeichnis ein.
– Suchen Sie die verfügbare Setup-Datei und doppelklicken Sie darauf.
– Ermöglichen Sie Windows, die Datei auszuführen (falls erforderlich).
– Lesen Sie die EULA (Endbenutzer-Lizenzvereinbarung) und stimmen Sie dem Installationsprozess zu.
– Folgen Sie den Anweisungen auf dem Bildschirm.
– Schließen Sie den Assistenten und führen Sie einen Systemneustart durch, damit die Änderungen wirksam werden.
Download