MikroTik RouterOS MIPSBE Firmware 6.44.5
Dosya tipi: Firmware.
Işleti̇m Si̇stemi: AnyOS.
Dosya adı: all_packages-mipsbe-6.44.5.zip.
Bit: 32/64 Bit.
Li̇sans: Ücretsiz.
Açıklama
MAJOR CHANGES IN v6.44.5:
– security – fixed vulnerabilities CVE-2018-1157, CVE-2018-1158;
– security – fixed vulnerabilities CVE-2019-11477, CVE-2019-11478, CVE-2019-11479;
– security – fixed vulnerability CVE-2019-13074;
Bu sürümdeki değişiklikler:
– bridge – correctly handle bridge host table;
– capsman – fixed CAP system upgrading process for MMIPS;
– capsman – fixed interface-list usage in access list;
– certificate – removed “set-ca-passphrase” parameter;
– cloud – properly stop “time-zone-autodetect” after disable;
– conntrack – fixed GRE protocol packet connection-state matching (CVE-2014-8160);
– defconf – automatically set “installation” parameter for outdoor devices;
– dhcpv6-client – fixed status update when leaving “bound” state;
– dhcpv6-server – fixed dynamic IPv6 binding without proper reference to the server;
– dhcpv6-server – override prefix pool and/or DNS server settings by values received from RADIUS;
– discovery – fixed CDP packets not including address on slave ports (introduced in v6.44);
– e-mail – properly release e-mail sending session if the server’s domain name can not be resolved;
– firewall – fixed fragmented packet processing when only RAW firewall is configured;
– firewall – process packets by firewall when accepted by RAW with disabled connection tracking;
– gps – strip unnecessary trailing characters from “longtitude” and “latitude” values;
– hotspot – moved “title” HTML tag after “meta” tags;
– ipv6 – improved system stability when receiving bogus packets;
– ovpn – added “verify-server-certificate” parameter for OVPN client (CVE-2018-10066);
– rb3011 – improved system stability when receiving bogus packets;
– rb921 – improved system stability (“/system routerboard upgrade” required);
– snmp – improved reliability on SNMP service packet validation;
– ssh – fixed non-interactive multiple command execution;
– supout – added IPv6 ND section to supout file;
– supout – added “pwr-line” section to supout file;
– supout – changed IPv6 pool section to output detailed print;
– winbox – do not allow setting “dns-lookup-interval” to “0”;
– wireless – improved DFS radar detection when using non-ETSI regulated country;
– wireless – improved installation mode selection for wireless outdoor equipment;
– wireless – updated “china” regulatory domain information;
– www – improved client-initiated renegotiation within the SSL and TLS protocols (CVE-2011-1473);
İndirme