NETGEAR GS752TS Switch Firmware 5.3.0.31
Type de fichier: Firmware.
Système d’exploitation: AnyOS.
Nom de fichier: GS728_752_TS_TPS_V5.3.0.31.zip.
Bit: 32/64 Bit.
Licence: Gratuit.
Description
Bug Corrections:
– Multicast packet with destination MAC address of 01:80:c2:00:00:1c and Ethernet type of 0x88CC causes loop in properly converged STP topology.
– Debugging URL of ‘devshell’ is accessible without authentication.
– Fiber port 50 goes down when copper port47/port48 links up.
– Cannot access switch via HTTPS when using the certificate generated by the switch.
Upgrade Procedure:
– Download the new firmware, store it in local PC, and remember its location in the PC’s file system.
– Unzip it to get the switch image.
– Go to GUI page “Maintenance > File Management > Dual Image > Dual Image Configuration”, find the backup (next-active) image.
– Support the backup-image is image1, then go to “Maintenance > Download > HTTP File Download”, set File Type as ‘Archive’, set Image Name as ‘Image1’, select the firmware file stored in local PC via Browser button, then click Apply button to start firmware downloading.
– The download will take several minutes. Do not power cycle the switch before and the success message shows up as below.
– Go to GUI page “Maintenance > File Management > Dual Image > Dual Image Configuration”, set ‘Unit Number’ as ‘All’; set ‘Image Name’ with Image1; check the checkbox of ‘Activate Image’, then Apply.
– Go to GUI page “Maintenance > File Management > Dual Image > Dual Image Status”, to double check the firmware version is correctly downloaded to image1 and image1 is the ‘next-active’ image. If not, go back to step 3 to download the switch image again.
– Go to GUI page ‘Maintenance > Reset > Device Reboot’, set ‘Reboot Unit No.’ as ‘All’ (default option); check the checkbox then click Apply button.
– After the switch is restarted, login the switch to double check whether the FW is upgraded correctly, via GUI page of “GUI page System > Management > System Information”.