Buffalo TS3400D NAS Firmware 1.83
Dateityp: Firmware.
Betriebssystem: Windows 10, Windows 7, Windows 8, Windows 8.1, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows Vista, Windows XP.
Dateiname: TS3000_series_FW_1.83.zip.
Bit: 64 Bit.
Lizenz: Kostenlos.
Beschreibung
Bug Fixes:
– Replication: Fixed a bug where a replication error occurs when disconnecting and reconnecting the USB drive after replication task was created.
– NFS: Fixed a bug where the TeraStation could not be accessed from specific NFS clients.
– Email Notifications: Fixed a bug where the email notification settings were configured properly even if a test email failed to be sent.
– System: Fixed a bug where the SMB log did not rotate.
– System: Fixed a bug where a NAS API error occurs and creating a backup task fails after applying settings from a USB drive.
– Backup: Fixed a bug where the TeraStation could not be detected when configuring backup on another TeraStation if too many users and/or groups were added for access restrictions.
– Backup: The backup target folder for a backup job where a different TeraStation is the backup source has been changed to “backup target folder”/”date”/”backup source folder”.
– Settings: Fixed a bug where access restrictions for shared folders could not be configured by a power user via Easy Admin.
– Settings: Improved the security level.
– Failover: Fixed a bug where configuring failover failed.
– Failover: Fixed a bug where a failover error message was displayed when cancelling the maintenance mode if the TeraStation has too many files.
– Samba: Fixed a bug where the access-restricted folder reserved for admin users could not be accessed after initializing settings.
Caution:
– Please consult your local technical support representative if you experience any problems caused by this firmware update.
– Do not turn the unit off until the update is finished. It will take several minutes. You will receive a message when the update is finished.
– USB drives are not mounted automatically after a firmware update. To mount them, unplug and then reconnect them.
How to Use the Updater:
1. Connect the TeraStation properly and configure the TeraStation and a computer to run the updater on the same network subnet. The subnet masks should be the same and the first three numbers of the IP addresses should be the same. The last number of the IP addresses should be different.
For example, if the IP address and subnet mask of the computer are
” 192.168.0.10 , 255.255.255.0 “
and the IP address and subnet mask of the TeraStation are
” 192.168.1.150 , 255.255.255.0 “
then the updater will _not_ work properly.
In this case, reconfigure the TeraStation’s IP address and subnet mask to
” 192.168.0.150 , 255.255.255.0 “.
Then they will be on the same subnet and the updater will work properly.
2. Close all applications. Also, stop or exit any firewall software.
3. Extract the downloaded file and run “TSUpdater.exe”. When a TeraStation is detected, an update window will open.
4. Select the TeraStation to update if multiple TeraStation are connected.
5. Click “Update” and enter the TeraStation’s admin password.
6. Click “OK”.
7. Transferring and updating the firmware will start. Wait until it finishes. The info LED will blink during the update.
8. When the update finishes, a message will be displayed.
Download